Maintenance-free titanium anode with its own power supply and unlimited lifetime to protect the enamel reservoir.
Each enameled vessel for heating water includes a magnesium anode that dissolves. The anode’s service life is approximately two years. After this time, replacement is required, which necessitates dismantling the flange and draining the heater. The maintenance-free titanium anode is a welcome alternative.
The CORREX MP titanium anode with external power source can be used for all stationary enameled vessels with a capacity of up to 300 liters. For continuous 24-hour protection, it is necessary to connect the anode outside the power source for the heater (lower DSM tariff), e.g. directly into a socket. The anode has a very low power consumption. After connection to a power source, the CORREX MP titanium anode operates throughout the entire lifetime of the heater.
- Potentiostat with plug for cathodic anticorrosion protection of enameled electric water heaters (interruption potentiostat with controlled protective current potential) with integrated signaling function and red/green LEDs
- Power and reference electrode coated with precious metal oxides
- Wear-free protective power supply; reference electrode for measuring the actual potential in the reservoir
- Minipotenciostat:
- Required potential: 2,3 V + 50 mV
- Pulse frequency: 100 Hz
- Interruption: 200 μs
- Nominal current (secondary): 100 mA
- Supply voltage (secondary): max. 10,6 V by 100 mA
Diameter: 2 mm
Length: 200 mm
Coating length: 100 mm
Threaded bolt: M8 x 30